Use of DEHP-Containing Medical Products and Urinary Levels of MEHP in Neonatal Intensive Care Unit Infants

Urinary MEHP levels increased monotonically with DEHP exposure. For the low-, medium-, and high-DEHP exposure groups, median (interquartile range) MEHP levels were 4 (18), 28 (58), and 86 ng/mL (150), respectively (p = 0.004). After adjustment for institution and sex, urinary MEHP levels among infants in the high exposure group were 5.1 times those among infants in the low exposure group (p = 0.03). CONCLUSION: Intensive use of DEHP-containing medical devices in NICU infants results in higher exposure to DEHP as reflected by elevated urinary levels of MEHP.